Product Function 1.13Type Arrhythmic Analysis, Multi-Lead ECG Waveforms Display in Phase, Real time S_T segment analysis, pacemaker detection Drug calculation and titration table 2. Efficient resistance to interference of defibrillator and electrosurgical cautery 3. SPO2 can testing for 0.1% Weak 4. RA-LL impedance Respiration 5. Trend Coexist Display 6. OxyCRG DyNamic View Display 8. Networking capacity 9. Options of printing, IBP, VGA and EtCO2, touch screen. 10. UP to 4 hours working capacity of built_in rechargeable battery. 11, 12.1"high resolution color TFT LCD display. 12, Large volume of tabular and graphic trends information storage and easy to recall. 13, Anti-ESU, anti- defibrillator 14, 6 Standard parameters:ECG,RESP,NIBP,SPO2,1_TEMP,PR/HR. 15, Capture dynamic waveforms.
Product Specification ECG Lead Mode: 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V) Lead selection: I, II, III, avR, avL, avF, V, Waveform: 2 ch Lead mode: 3 Leads ( R, L, F or RA, LA, LL) Lead selection: I, II, III, Waveform: 1 ch Gain: ´2.5mm/mV, ´5.0mm/mV, ´10mm/mV, ´20mm/mV, auto HR and Alarm Range Adult: 15 ~ 300 bpm Neo/Ped: 15 ~ 350 bpm Accuracy : ± 1% or ± 1bpm,which great Resolution: 1 bpm Sensitivity: > 200 (uV P-P) Differential Input Impedance: > 5 MΩ CMRR Monitor: > 105 dB Operation: > 105 dB Diagnosis: > 85 dB Electrode offset potential: ±300mV Leakage Current: < 10 uA Baseline Recovery: < 3 S After Defi. ECG Signal Range: ±8 m V ( Vp-p ) Bandwidth Surgery: 1 ~ 15 Hz Monitor: 0.5 ~ 35 Hz Diagnostic: 0.05 ~ 100 Hz Calibration Signal: 1 (mV p-p), Accuracy:±5% ST Segment Monitoring Range: Measure and Alarm -2.0 ~ +2.0 mV ARR Detecting Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC Alarm: Available Review: Available RESPARATION Method: Impedance between R-F(RA-LL) Differential Input Impedance: >2.5 MΩ Measuring Impedance Range: 0.3~5.0Ω Base line Impedance Range: 0 - 2.5 KΩ Bandwidth: 0.3 ~ 2.5 Hz Resp. Rate Measuring and Alarm Range Adult: 0 ~ 120 rpm Neo/Ped: 0 ~ 150 rpm Resolution: 1 rpm Accuracy : ±2 rpm Apean Alarm: 10 ~ 40 S NIBP Method: Oscillometric Mode: Manual, Auto, STAT Measuring Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min) Measuring Period in STAT Mode: 5 Min Pulse Rate Range: 40 ~ 240 bpm Alarm Type: SYS, DIA, MEAN Measuring and alarm range Adult Mode SYS: 40 ~ 270 mmHg DIA: 10 ~ 215 mmHg MEAN: 20 ~ 235 mmHg Pediatric Mode SYS: 40 ~ 200 mmHg DIA: 10 ~ 150 mmHg MEAN:20 ~ 165 mmHg Neonatal Mode SYS: 40 ~ 135 mmHg DIA:10 ~ 100 mmHg MEAN:20 ~ 110 mmHg Resolution Pressure:1mmHg Accuracy Pressure Maximum Mean error: ±5mmHg Maximum Standard deviation: ±8mmHg Overpressure Protection Adult Mode: 297±3 mmHg Pediatric Mode: 240±3 mmHg Neonatal Mode: 147±3 mmHg SpO2 Measuring Range: 0 ~ 100 % Alarm Range: 0 ~ 100 % Resolution: 1 % Accuracy : 70% ~ 100% ±2 % 0% ~ 69% unspecified Actualization interval: about 1 Sec. Alarm Delay: 10 Sec. Pulse Rate Measuring and Alarm Range: 20~300bpm Resolution: 1bpm Accuracy : ±2bpm TEMPERATURE Channel: 1 Measuring and Alarm Range: 0 ~ 50 °C Resolution: 0.1°C Accuracy : ±0.1°C Actualization interval: about 1 Sec. Average Time Constant:<10 Sec. IBP(Optional) Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2 Measuring and alarm range ART: 0 ~ 300 mmHg PA: -6 ~ 120 mmHg CVP/RAP/LAP/ICP: -10 ~ 40 mmHg P1/P2: -10 ~ 300 mmHg Press Sensor Sensitivity: 5 uV/V/mmHg Impedance: 300-3000Ω Resolution: 1 mmHg Accuracy : ±2% or ±1mmHg, which great Actualization interval: about 1 Sec.