Features: 1,Waterproof design appearance,low power consumption,without air fan and silence,use 13-20V output DC,battery working time is at least 4hours,recharge time is 2.5hours.Suitable for medical field rescue,ambulance,move and transit. 2,display mode of big font,trend review,ECG 7 lead,support one key operation,touchable screen is optional.Suitable for all working places,can used for neonate,child,adult,support mode of diagnose,monitor,operation. 3,13 type arrhythmic analysis,7-lead ECG waveform display in phase. 15 type drug calculation and titration table. 4,efficient resistance to interference of defibrillator and electrosurgical cautery,respiration can choose I\II,meet requirement of operation,ward. 5,use digital SpO2 technology,can test for 0.1% weak,high accuracy. 6,anti-ESU,anti-defibrillator,RA-LL impedance respiration,digital filtering. 7,double over-pressure NIBP protect,temperature drift.
Specifications:
1.ECG Lead mode: 3-lead or 5-lead cable 3-lead:RA,LA,LL,lead way:I,II,III 5-lead:RA,LA,LL,RL,V,lead way:I,II,III,aVR,aVL,aVF,V gain:´250,´500,´1000,´2000 Heart rate range:adult:15 ~ 300bpm (pulse/min.) neonate/child:15 ~ 350 bpm(pulse/min.) accuracy:±1% or ±1bpm, resolution:1 bpm(pulse/min.) sensitivity >200 uV(peak-to-peak value) Input resistance >5(mge) bandwidth: Diagnostic mode:0.05~130Hz Monitor mode:0.5~40Hz Operation mode:1~20Hz Common mode rejection ratio Diagnostic mode:>90 dB Monitor mode:>100 dB Operation mode:>100 dB The electrode polarization voltage range ±300mV Pacemaker pulse detection Can test following: range:±2 mV ~ ±700mV width:0.1ms ~ 2ms rise time:10us~100µs Pacemaker pulse suppression When turn on pacemaker pulse,can restrain following data, does not influence pulse rate calculation: range:±2 mV ~ ±700mV width:0.1ms ~ 2ms rise time:10us ~ 100µs Baseline recovery time after defibrillation< 3 seconds Sign range ±8 mV (peak-to-peak value) Calibrating signal 1mV(peak-to-peak value),accuracy ±5% ST measurement Measure range:-2.0mV ~ +2.0mV Measure accuracy:in range of -0.8 mV~+0.8mV the tolerance is ±0.02mV or ±10% take bigger one. Undefinition in other range. 2.Respiration Way: RA-LL impedance and RA-LA impedance. Range: 0.3~3Ω Base impedance range 200~4000Ω Band width 0.1~2.5Hz Respiration rate range adult:2~120BrPM child and neonate:2~150 BrPM resolution:1 BrPM accuracy:±2 BrPM Apnea alarm 10~40 seconds 3.NIBP Technology:Oscillometric Mode: manual/auto/STAT Measurement inerval time under auto mode is 1,2,3,4,5,10,15,30,60,90,120,180,240,480 minutes. Measurement time under STAT mode is 5 minutes. Pulse rate range 40~240 bpm Measurement range and accuracy range adult SIS 40~270mmHg DIA 10~215mmHg mean 20~235mmHg child SIS 40~200mmHg DIA 10~150mmHg mean 20~165mmHg neonate SIS 40~135mmHg DIA 10~100mmHg mean 20~110mmHg Static pressure range 0~300mmHg Static pressure accuracy ±3mmHg Blood pressure accuracy: maximum average error ±5mmHg;largest standard deviation 8mmHg Over-pressure protect Adult mode 300 mmHg Child mode 240 mmHg Neonate mode 150 mmHg 4.SpO2
range 0~100% resolution 1% accuracy 70~100%:±2;0%~69%:undefinition Pulse rate range 20~300bpm resolution 1bpm accuracy ±3bpm 5.TEMP Suitable temperature probe YSI,CYF Channel number: 1 channel range 0~50°C resolution 0.1°C accuracy ±0.1°C(do not include error of probe)
Standard configuration: 1. main unit(include battery) for animal 1pc 2.5-lead ECG cable with clip 1pc 3.TEMP rectal probe 1pc 4.Animal NIBP cuff 1pc 5.NIBP tube 1pc 6.Animal SpO2 sensor 1pc 7.power cord 1pc