12" Inch Multi-Parameter Patient Monitor

Classification: Patient Monitor
Type: Patient Monitor
Certification: CE, MSDS, ISO13485
Group: All People
Transport Package: Cartoon Box
Trademark: POCVODA
Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
PV-2000D
Origin
China
Production Capacity
500000/Year

Product Description

Specification:
1. Standard parameters:ECG,RESP,NIBP,SPO2,PR/HR,TEMP.
2.13 types Arrhythmic Analysis, Multi-lead ECG waveforms display in Phase, 15 types Drug calculation and titration table.
3.Anti-ESU, anti-defibrillator; RA-LL impedance.
4.SPO2 can testing for 0.1% weak,high accuracy.
5.Unique breathing measurement technology, real-time monitoring, intelligent filter design, eliminate interference, measuring respiratory accurately.
6.Trend Coexist interface for all parameter to observe easily.
7.OxyCRG Dynamic View display, More intultive with all parameters.
8.Platform scalable with cable or wireless connecting to central monitoring.
9.Printer /Recorder is optional for real-time printing.
10.Brief operation interface, Touchscreen is optional.
Up to 2-5 hours working capacity of built-in rechargeable Li-ion battery.
  1. 12.1"high resolution color TFT LCD display.
  2. Holographic waveform trends playback for 2 weeks and 12 hours off electricity saving.
    13.Built-in networking to realize central monitoring function.
14.Optional: Touchscreen, VGA, 2-IBP, HDMI, ETCO2.
15.System start up only need 10 seconds with ARM-A5 Nuclear technology.

Standard accessory:

5-lead ECG cable                              1pc
Surface temp.probe                             1pc
    Adult NIBP cuff                                 1pc
NIBP tube                                     1pc
Adult SpO2 sensor                              1pc
Power cord                                     1pc
Electrode                                       5pcs
User manual                                    1pc



Specifications
 
  1. ECG

Lead Mode: 5 Leads or 3 Leads
3 Leads:RA,LA,LL,Lead mode:I,II,III
5 Leads:RA,LA,LL,RL,V,Lead mode:I,II,III,aVR,aVL,aVF,V
Gain  ´250,´500,´1000,´2000

Heart Rate :

Range:            Adult:15 ~ 300bpm ;   Neonate / Pediatric:15 ~ 350 bpm
Accuracy:±1%or ±1bpm,
Resolution:1 bpm
Sensitivity  >200 uV
Differential Input Impedance >5MΩ
Bandwidth
Diagnostic:0.05~130Hz
Monitor:0.5~40Hz
Surgery:1~20Hz

 
  1. RESP

Method: Impedance between R-F(RA-LL)
Scope of base impedance:200~4000Ω
Bandwidth: 0.1~ 2.5 Hz

RESP
Range: Adult:2~120BrPM   Neonate / Pediatric :2~150 BrPM
Resolution:1 BrPM
Accuracy:±2 BrPM
Suffocation warning:10~40s
 
  1. NIBP

Method: Oscillometric
Mode: Manual, Auto, STAT
Measuring interval in AUTO MODE:1,2,3,4,5,10,15,30,60,90,120,180,240,480 MINS
Measuring interval in STAT MODE 5 MINS
PR range  40~240 bpm
Measuring Range and Resolution
Adult        SYS         40~270mmHg
                        DIA         10~215mmHg
                        MEAN      20~235mmHg
PED        SYS         40~200mmHg
                        DIA         10~150mmHg
                        MEAN              20~165mmHg
                NEO        SYS              40~135mmHg
                                DIA               10~100mmHg
                                MEAN              20~110mmHg
STATIC NIBP range: 0~300mmHg
Static NIBP accuracy:±3mmHg
Max Average tolerance ±5mmHg;Max. Standard tolerance: 8mmHg
Over-pressure protection:
Adult mode:              300 mmHg
Ped mode:         240 mmHg
Neo mode:                150 mmHg

 
  1. SpO2

Measuring range:             0~100%
Resolution:                 1%
Accuracy:                  70~100%:±2;0%~69%:
Pulse Rate:
Measuring range:     20~300bpm
Resolution:                       1bpm
Accuracy:                  ±3bpm

 
  1. TEMP

Channels: 2
Measuring:
Range:     0~50°C
Resolution                0.1°C
Accuracy :    ±0.1°C(sensor tolerance no not included )


6. Power

Adapter
Input:AC 90 V~240V, 50/60Hz
Output:DC 12V-20V
Built-in Battery:
TYPE:14.8V, 2200mAH Li-ion rechargeable battery
Operating time:3.5-4 hours working time under full power
Charging time:2 hours
 
    1. IBP(Optional)
Label                ART, PA, CVP, RAP, LAP, ICP, P1, P2
        Measuring and alarm range
ART         0 ~ 300 mmHg,  PA -6 ~ 120 mmHg
CVP/RAP/LAP/ICP  -10 ~ 40 mmHg , P1/P2 -10 ~ 300 mmHg                     Press Sensor
Sensitivity       5  uV/V/mmHg, Impedance      300-3000Ω
        Resolution                          1 mmHg
        Accuracy                    ±2% or ±1mmHg, which great
Actualization interval        about 1 Sec.
 

8. CO2(Optional)

       Measuring and alarm range      0% ~ 13%
       Resolution                                1 mmHg
Accuracy                                         2 mmHg @ < 5.0% CO (at ATPS)
RR                          3 - 150 bpm

12&quot; Inch Multi-Parameter Patient Monitor12&quot; Inch Multi-Parameter Patient Monitor12&quot; Inch Multi-Parameter Patient Monitor12&quot; Inch Multi-Parameter Patient Monitor

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Main Products
ICU Ventilator, Patient Monitor, Chison Portable, Infustion Pump, Aed, Defibrillator, Electrosurgical, Ultrasound Probe, Wireless Probe, Detal Equipment
Registered Capital
1000000 RMB